Key-Image-mit-Shadow---breit-English

OPC 10

OPC 10

The premium high performance collectors for the maximum energy yield.

 

Specials
Tichelmann
Frame Alu
Reflector Parabolic
Warranty 10 years
All RAL colors
Applications
SFH
MFH
Camping
Mountain cabin
Business
Industry
Utilisations
Hot water
Heating
Process heat
Solar cooling
Technical data
OPC 10 OPC 15
Length 1700 1700 mm
Width 850 1250 mm
Height (incl. frame)
97 97 mm
Gross surface
1.45 2.13 m2
Active absorber surface 360° 1.67 2.50 m2
Aperture surface
1.15 1.72 m2
Weight 32 45 kg
Absorber/Glass 360° Borosilicate 3.3
Frame Aluminum
Coating 9-fold copper-nitrite/alu/steel
Connections 6 x 3/4“
Total capacity
2.1 3.1 Ltr
Allowed working pressure
10 bar
Volume flow recommended
0.7 1.1 Ltr/Min/Mod
Performance OPC 10 OPC 15
Peak performance *
934 W 1416 W
Max. performance collector
865 W 1311 W
Efficiency values (G=800W/m2/aperture)
Eta (x=0.00) 0.78, (x=0.05) 0.69, (x=0.10) 0.57
Angular correction factors
0° 10° 20° 30° 40° 50° 60° 70° 90°
K(0)trans 1.0 1.0 1.0 0.9 0.84 0.93 1.08 1.03 0.0
* corrected with IAM 60 degrees

Collector performance

During winter an in periods with lower solar irradiations often only 400W/m2 are available. The temperature differences between collector and outside are very high. In the chart below you will find out how the energy performance of the collector changes according to the solar irradiation and temperature differences. The values are considered under direct irradiation.
Collector output per module [W] OPC 10 radiation power 
OPC 15 radiation power
(ϑm-ϑa) [K] 400 W/m2 700 W/m2 1‘000 W/m2 400 W/m2 700 W/m2 1‘000 W/m2
10 329 W 589 W 848 W 506 W 899 W 1293 W
30 294 W 554 W 813 W 464 W 857 W 1250 W
50 257 W 516 W 776 W 414 W 807 W 1201 W

Dimensioning of collector areas, solar tank and heat exchanger

In the following chart you can see recommended values for the dimensioning. In any case we recommend to use simulating software to calculate the energy yield and layout of your solar system.
OPC 10 Hot water generation
Hot water generation with heating
No. of persons
Rec. aperture surface [m2] No. of collectors
Rec.
tank size [l]
Size (min.) heat exchanger [m2] Rec. aperture surface [m2] No. of collectors
Recommended PHE
Assumed heating output
2 2.30 2 200 0.30 3.45 3 BB40 up to 25 kW
3 3.45 3 300 0.45 4.60 / 5.75 4 / 5 BB40 up to 25 kW
4 3.45 3 300 0.45 5.75 5 BB40 up to 25 kW
5 4.60 4 400 0.60 5.75 / 6.90 5 / 6 BB40 up to 25 kW
6 4.60 / 5.75 4 / 5 400 / 500 0.60 / 0.75 6.90 / 8.05 6 / 7 BB40 up to 25 kW
7 5.75 / 6.90 5 / 6 500 0.75 / 0.90 8.05 / 9.20 7 / 8 BB100 up to 50 kW
8 6.90 / 8.05 6 / 7 500 0.90 / 1.05 10.35 9 BB100 up to 50 kW
OPC 15 Hot water generation
Hot water generation and heating
No. of persons
Rec. aperture surface [m2] No. of collectors
Rec. tank size [l] Size (min.) heat exchanger [m2] Rec. aperture surface [m2] No. of collectors
Recommended PHE
Assumed heating output
2 3.44 2 300 0.42 3.44 / 5.16 2 / 3 BB40 up to 25 kW
3 3.44 2 300 0.42 5.16 3 BB40 up to 25 kW
4 3.44 / 5.16 2 / 3 300 / 400 0.42 / 0.63 5.16 / 6.88 3 / 4 BB40 up to 25 kW
5 5.16 3 400 / 500 0.63 6.88 / 8.60 4 / 5 BB40 up to 25 kW
6 6.88 4 500 0.84 8.60 / 10.32 5 / 6 BB40 up to 25 kW
7 6.88 / 8.60 4 / 5 500 0.84 / 1.05 10.32 / 12.04 6 / 7 BB100 up to 50 kW
8 8.60 5 500 1.05 12.04 / 13.76 7 / 8 BB100 up to 50 kW
Note: These data are recommendations and not binding. This information relates to central europe >46 degrees 30 min N and <56 degrees 30 min N.
Number Stücks in packaging:1
Number Stücks in box:1

Language